IndoGama.com

LABORATORY, SURVEY, EQUIPMENTS & REAGENTS (ILabS=>Indonesia Laboratory Suppliers)

HETTICH, Centrifuge, Mikro 220 + 1158L + 2031

HETTICH Centrifuge Mikro 220HETTICH, Centrifuge, Mikro 220 + 1158L + 2031

Hettich MIKRO Centrifuge 220 is a powerful, compact benchtop centrifuge for processing microlitre tubes of 0.2 ml to
2.0 ml. 2.0 ml
It is used in genetic research, virology and bacteriology. It is used in genetic research, virology and bacteriology. In an angle rotor, RCF values up to 31,514, in a swing-out rotor up to 18,516 can be generated. In an angle rotor, RCF values up to 31.514, in a swing-out rotor up to 18.516 can be generated. A drum rotor allows spinning a maximum of 60 microlitre tubes per run. A drum rotor spinning allows a maximum of 60 microlitre tubes per run.

Dimensions : 313 x 330 x 420 mm

(more…)

HETTICH, Centrifuge, Mikro 200R + 2424 + 2031

HETTICH Centrifuge Mikro 200RHETTICH, Centrifuge, Mikro 200R + 2424 + 2031

The MIKRO 200 R ranks among the fastest in its class Centrifuges. Not only is it fast, the MIKRO 200 R also refrigerates quickly: to +4°C with the Fast Cool function in 10 to 15 minutes. Not only is it fast, the MIKRO 200 R So refrigerates quickly: to +4 ° C with the Fast Cool function in 10 to 15 minutes. Even thermosensitive samples can be gently centrifuged thanks to highly reliable refrigeration. Even thermosensitive samples can be gently centrifuged thanks to highly reliable refrigeration.

Accessories:

(more…)

HETTICH, Centrifuge, Hematokrit, Model : 210 + 2076

HETTICH Haematokrit-210HETTICH, Hematokrit, Model : 210 + 2076

At 16,060g sedimentation is completed in just a little over 6 minutes. At any rate, a run time of 10 minutes is sufficient. The rotor comes to a braked standstill. Each capillary is secured within its own chamber and supported by a holding tray. This holding tray serves to contain glass shards and any leakage should a tube break. It is easy to clean and disposable in the case of glass breakage. Capillaries, to be used for quantitative buffy coat analysis are centrifuge in the 20-place rotor prior to further analysis.
(more…)

Hettich, Centrifuge EBA 20

HETTICH EBA-20Practical and handy, the EBA 20 is ideal for a small quantity of samples.
Microprocessorcontrolled centrifuge with an 8-place angle rotor.
Max. capacity 8 x 15 ml
Max. RPM (speed) 6,000 min-1
Max. RCF 3,461
Running time 1 – 99 min , continuous run, short cycle mode (impulse key)
Dimensions (HxWxD) 216 x 231x 292 mm
Weight approx. 4 kg

ask for detail

Download brochure .pdf 394 KB