IndoGama.com

LABORATORY, SURVEY, EQUIPMENTS & REAGENTS (ILabS=>Indonesia Laboratory Suppliers)

CENTRIFUGE

HETTICH, Centrifuge, EBA 200

HETTICH CENTRIFUGE EBA-20

HETTICH, Centrifuge, EBA 200

Berikut ini spesifikasi dari Hettich EBA 200:

Consumption : 65 VA

Dimension (H x W x D) : 228 x 261 x 353 mm

Weight : 9 Kg

Max capacity : 8 x 15 ml

Max RMP/RCF : 6,000/3,461 Fixed 8,000/6,153 Fixed (20S)

Temperature : N/A

(more…)

HETTICH, Centrifuge, Rotofix 32 A

HETTICH Centrifuge Rotofix 32_AHETTICH, Centrifuge, Rotofix 32 A

Being the centrifuge of choice for physicians and small laboratories the Rotofix 32 carries out virtually every routine task required in practice. In the medical field it may be used for both clinical chemistry and cytology

–        Frequency : 50-60 Hz

–        Max Capacity : 4 x 100 ml

–        Max. RCF : 4,186

–       Max. RPM (speed) : 6,000 min-1

(more…)

HETTICH, Centrifuge, Mikro 220 + 1158L + 2031

HETTICH Centrifuge Mikro 220HETTICH, Centrifuge, Mikro 220 + 1158L + 2031

Hettich MIKRO Centrifuge 220 is a powerful, compact benchtop centrifuge for processing microlitre tubes of 0.2 ml to
2.0 ml. 2.0 ml
It is used in genetic research, virology and bacteriology. It is used in genetic research, virology and bacteriology. In an angle rotor, RCF values up to 31,514, in a swing-out rotor up to 18,516 can be generated. In an angle rotor, RCF values up to 31.514, in a swing-out rotor up to 18.516 can be generated. A drum rotor allows spinning a maximum of 60 microlitre tubes per run. A drum rotor spinning allows a maximum of 60 microlitre tubes per run.

Dimensions : 313 x 330 x 420 mm

(more…)

HETTICH, Centrifuge, Mikro 200R + 2424 + 2031

HETTICH Centrifuge Mikro 200RHETTICH, Centrifuge, Mikro 200R + 2424 + 2031

The MIKRO 200 R ranks among the fastest in its class Centrifuges. Not only is it fast, the MIKRO 200 R also refrigerates quickly: to +4°C with the Fast Cool function in 10 to 15 minutes. Not only is it fast, the MIKRO 200 R So refrigerates quickly: to +4 ° C with the Fast Cool function in 10 to 15 minutes. Even thermosensitive samples can be gently centrifuged thanks to highly reliable refrigeration. Even thermosensitive samples can be gently centrifuged thanks to highly reliable refrigeration.

Accessories:

(more…)

HETTICH, Benchtop Centrifuge, Model : Mikro 120

HETTICH Benchtop Centrifuge Mikro-120Hettich Mikro 120 Benchtop Centrifuge with Rotor and Microtubes

A compact and dependable micro-centrifuge requiring very little bench space. The small, powerful Hettich Mikro 120 offers a 24-place rotor for microliter tubes making it the perfect tabletop centrifuge for all your research applications.
–    Max. Capacity : 24 x 1.5/2.0 mL
–    Max. RPM/RCF : 14,000/18,407
–    Dimensions : 199 x 231 x 292 mm (8” x 9” x 11.5”)
–    Weight : 7 Kg (15 lbs)
–    Place Angle Rotor, Model : GB-A1212 :

(more…)

HETTICH, Centrifuge, Hematokrit, Model : 210 + 2076

HETTICH Haematokrit-210HETTICH, Hematokrit, Model : 210 + 2076

At 16,060g sedimentation is completed in just a little over 6 minutes. At any rate, a run time of 10 minutes is sufficient. The rotor comes to a braked standstill. Each capillary is secured within its own chamber and supported by a holding tray. This holding tray serves to contain glass shards and any leakage should a tube break. It is easy to clean and disposable in the case of glass breakage. Capillaries, to be used for quantitative buffy coat analysis are centrifuge in the 20-place rotor prior to further analysis.
(more…)

Hettich, Centrifuge EBA 20

HETTICH EBA-20Practical and handy, the EBA 20 is ideal for a small quantity of samples.
Microprocessorcontrolled centrifuge with an 8-place angle rotor.
Max. capacity 8 x 15 ml
Max. RPM (speed) 6,000 min-1
Max. RCF 3,461
Running time 1 – 99 min , continuous run, short cycle mode (impulse key)
Dimensions (HxWxD) 216 x 231x 292 mm
Weight approx. 4 kg

ask for detail

Download brochure .pdf 394 KB

Eppendorf, Centrifuge, model 5702 series

image0013.jpgCentrifuge, Eppendorf, model 5702 series
Model 5702, 5072 R (Referigerated), 5702 RH (precise temperature control)
Centrifuge, Eppendorf, model 5702 series
Model 5702, 5072 R (Referigerated), 5702 RH (precise temperature control)
Eppendorf designed a new centrifuge that can quickly and safely carry out routine centrifugation in small, medical and cell culture labs. All rotors used in the Centrifuge 5702 can also be used in 5072R & 5702 RH including the versatile A-4-38 swing-bucket rotor, which can centrifuge up to four 85 ml tubes in aerosol-tight round buckets at almost 3,000 x g. If increased capacity is required, the A-4-38 can also be used with rectangular buckets and a variety of adapters (e.g. for 24 x 15 ml glass tubes). The fixed-angle rotor F-35-30-17 is available in two versions with a capacity of up to 30 x 15 ml.
The simple A-8-17 swing-bucket rotor for 15 ml tubes (Falcon® tubes and test tubes) rounds off the program. The Centrifuge 5702 R, just like all refrigerated centrifuges from Eppendorf, also offers the proven stand-by refrigeration and the “fast-temp” special function. Temperatures between -9°C and +40°C can be quickly reached in this way. The Centrifuge 5702 RH is unique in its temperature control capacity, that can consistently maintain temperatures higher than room temperature. Temperature-sensitive cells or cell cultures can be centrifuged under defined conditions, especially in the temperature range around 37°CAll three 5702 models are uncommonly versatile, despite the very small dimensions, and can process greater volumes than comparable models.
For the Centrifuges 5702 R and 5702 RH, two program keys illuminated with blue light when activated provide additional functions. They should provide the user with the possibility to save the parameters of two standard centrifugation processes. By activating a SOFT function with shorter startup and braking times, the yields can be increased for special blood, urine or cell culture centrifugation. In addition, the Centrifuges 5702 R and 5702 RH offer an “at set rpm” function. When this is activated, the device only begins the countdown for the set run time when the desired rotational speed has been reached. Falcon ®: Registered trademark of Becton Dickinson.
ask for detail
.