IndoGama.com

LABORATORY, SURVEY, EQUIPMENTS & REAGENTS (ILabS=>Indonesia Laboratory Suppliers)

Socorex, Micropipette Acura ®

SOCOREX MICROPIPETTE ACURAAcura ® 815
The air displacement fixed volume pipettes come with all good features of the new instrument generation. These include slim ergonomic design, ultra-soft plunger stroke, autoclavability, and much more. Available in a wide selection of 1,5  and 10 µL ultra-micro volumes, micro sizes from 20 to 1000 µL, and macro volumes models of 2 mL, 2.5 mL, 5 mL and 10 mL.

Acura ® 825/835
Adjustable volume micro and macropipettes, fix and digital micropipettes
Equipped with a precision digital display, the new line is continuously adjustable down to a very fine volume resolution. Single-handed volume setting is easy when the other hand is bussy. Measuring unknown volumes by aspiration is also possible with a high degree of accuracy. Click-stops, together with freely rotating smartie plugger button cap ensure setting stability while pipetting.

Acura ® 855

Multi 8 or 12 channel adjustable volume microcropipettes.

Prices:

Acura ® 815 fix micropipette volume 1 ul, 5 ul, 10 ul, 20 ul, 25 ul, 50 ul, 100 ul, 200 ul, 250 ul, 500 ul, or 1000 ul. Rp 3.500.000,- (all item)

Acura ® 825 digital (variable) micropipette volume 0,1-2 ul or 0,5-10 ul. Rp 5.000.000,-

Acura ® 825 digital (variable) micropipette volume 1-10ul, 2-20 ul, 5-50 ul, 10-100 ul, 20-200 ul or 100-1000 ul. Rp 4.700.000,-

Acura ® 835 digital (variable) macropipette volume 0,2-2 ml, 0,5-5 ml or 1-10 ml. Rp 4.290.000,-

Acura ® 835 fix macropipette volume 2 ml, 2,5 ml, 5 ml or 10 ml. Rp 3.420.000,-

Acura ® 855 digital multi 8 channel micropipette volume 0,5-10 ul. Rp 11.110.000,-

Acura ® 855 digital multi 8 channel micropipette volume 5-50ul, 20-200 ul or 40-350 ul. Rp 10.415.000,-

Acura ® 855 digital multi 12 channel micropipette volume 0,5-10 ul. Rp 12.775.000,-

Acura ® 855 digital multi 12 channel micropipette volume 5-50ul, 20-200 ul or 40-350 ul. Rp 11.960.000,-

Harga Socorex, Micropipette Acura diskon 10% belum termasuk PPn (harus dengan PPN) Franko Yogyakarta, Berlaku 1 Januari 2015.  Harga bisa berubah sewaktu-waktu.

ask for detail

HANNA, Photometer, Model : HI 83206

HANNA HI83206

HI 83206

HANNA, Photometer, Model : HI 83206

Multiparameter Photometer for Environmental Testing

specifications :

Light Source : up to 5 tungsten lamps with different narrow band interference filters.
Light Detector : silicon photocell
Power Supply : external 12 VDC power adapter or built-in rechargeable battery
Environment : 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Dimensions : 235 x 200 x 110 mm (9.2 x 7.87 x 4.33″)
Weight : 0.9 Kg (2 lbs.)

Harga :  call , Harga tidak termasuk PPN franko Yogyakarta, Harga dapat berubah sewaktu-waktu.

ask for detail

HANNA, Photometer, Model : HI 83225

 

HANNA HI83225

HANNA HI83225

HANNA, Photometer, Model : HI 83225

Nutrient Analysis Photometer for Greenhouses and Hydroponics, Advanced

Harga : Rp.14.030.000,- , Harga tidak termasuk PPN franko Yogyakarta, berlaku 1 April 2018, Harga dapat berubah sewaktu-waktu.

specifications :

Light Source : up to 5 tungsten lamps with different narrow band interference filters.
Light Detector : silicon photocell
Power Supply : external 12 VDC power adapter or built-in rechargeable battery
Environment : 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Dimensions : 235 x 200 x 110 mm (9.2 x 7.87 x 4.33″)
Weight : 0.9 Kg (2 lbs.)

 

ask for detail

HANNA, COD Meter, Model : HI 83099

HANNA COD Meter HI83099

HANNA COD Meter HI83099

HANNA, COD Meter, Model : HI 83099

COD and Multiparameter Bench Photometer

Harga : Rp. 28.310.000,- , Harga tidak termasuk PPN franko Yogyakarta, berlaku 1 April 2018, Harga dapat berubah sewaktu-waktu.

spesifications :

Light Source : tungsten lamps with narrow-band interference filters
Light Detection : silicon photocell
Power Supply : external 12 VDC power adapter or built-in rechargeable battery
Auto-off : after 10 min of non-use in measuring mode; after 1 hour of non-use in calibration mode with last reading reminder
Environment : 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Dimensions : 235 x 200 x 110 mm (9.2 x 7.87 x 4.33)
Weight : 0.9 Kg (2 lbs.)

ask for detail

HANNA, COD Reactor, Model : HI 839800

 

HANNA COD Reactor HI839800

HANNA, COD Reactor, Model : HI 839800

COD REACTOR and Test Tube Heater 2008 Series
Harga : Rp. 17.500.000,- , Harga tidak termasuk PPN franko Yogyakarta, berlaku 1 April 2018, Harga dapat berubah sewaktu-waktu.

specifications:

Temperature of Reaction :105°C or 150°C (221°F or 302°F)
Temperature Stability :±0.5°C (±0.9°F)
Temperature Range :-10°C to 160°C (14°F to 320°F)
Accuracy :±2°C (±3.6°F)
Capacity :25 vials (dia 16 x 100 mm), one receptacle for a stainless steel reference thermometer

Read the rest of this entry →

HANNA, DO Meter, Model : HI 9142

HANNA DO Meter HI9142

HANNA DO Meter HI9142

HANNA, DO Meter, Model : HI 9142

DO Meter

Harga : Rp. 12.140.000,- , Harga tidak termasuk PPN franko Yogyakarta, berlaku 1 April 2018, Harga dapat berubah sewaktu-waktu.

specifications :

Range : 0.0 to 19.9 mg/L (ppm)

Resolution : 0.1 mg/L
Accuracy : ±1.5% FS
Typical EMC : ±0.8 mg/L
Deviation : with 4 m cable probe
Calibration : Manual, 1 or 2 point (zero and slope)
Temperature Compensation :  Automatic, 0 to 30°C  (32 to 86°F)

HANNA, DO Meter, Model : HI 9146

HANNA DO Meter HI9146

HI 9146 indogama

HANNA, DO Meter, Model : HI 9146

DO Meter

specifications :

Range : 0.00 to 45.00 mg/L O2
0.0 to 300 %O2
0.0 to 50.0 °C
Resolution : 0.01 mg/L O2
0.1 %O2
0.1 °C
Accuracy (@25°C/77°F) : ±1.5% Full Scale mg/L O2
±1.5% Full Scale %O2
±0.5 °C

HANNA, DO Meter, Model : HI 9147

HANNA DO Meter HI 9147

HI 9147 indogama

HANNA, DO Meter, Model : HI 9147

DO Meter

specifications :

Range : 0.0 to 50.0 mg/L (ppm) O2
0 to 600 % O2
-5.0 to 50.0°C
Resolution : 0.1 mg/L or 1% (O2) / 0.1°C
Accuracy : ±1% of reading (O2) / ±0.2°C
Typical EMC Deviation : ±2% of reading (O2) / ±1°C
Calibration : Manual, in saturated air
Temperature Compensation :  Automatic, from -5 to 50°C (23 to 122°F)
Salinity Compensation : 0 to 51 g/L (resolution 1 g/L)

HANNA, DO Meter, Model : HI 93732N

HANNA HI 93732N

HI 93732N

Hanna, DO Meter, Model : HI 93732N

DO Meter hi 93732n

specifications :
Range :   0.0 to 10.0 mg/L (ppm)
Resolution :  0.1 mg/L
Accuracy :  ±0.2 mg/L ± 3% of reading
Typical EMC : ±0.1 mg/L
Deviation
Light  : Source Light Emitting Diode @ 470 nm
Method : Adaptation of the Standard Methods for
the Examination of Water and Wastewater
(18th edition), azide modified Winkler
method. The reaction between dissolved
oxygen and the reagent causes a yellow
tint in the sample. hi 93732n

Juknis DAK SMU 2013

Petunjuk Teknis (Juknis) Dana Alokasi Khusus (DAK) SMU 2013

1. Mikroskop Elektrik :
Persyaratan :

Lensa obyektif 4x, 10x, 40, dan 100x, Lensa okuler 5x dan 10x. Kondensor berupa cermin datar dan cermin cekung, diafragma iris, konstruksi logam kuat dan kekar, meja horizontal, pengatur focus kasar dan halus, tersimpan dalam peti kayu yang dilengkapi silica gel dan petunjuk pemakaiannya. Sumber cahaya dari lampu elektrik.

Type yang sesuai :

Microscope XZS 107 BN

specification :

45mm DIN achromatic objective:4x,10x,40x(s) ,100x(s,oil)
wide field plane-scope eyepiece:WF10X,WF16X;
Total magnification:40x-1600x direct/ 107x-2680x from camera;
interpupillary distance:55-75mm;45°inclined,360°rotatable;
double layer mechanical stage:142mmx132mm,moving range X-Y:75x50mm;
dia2-30mm iris diaphragm and  filter; Bright field condensor :N.A. 1.25 (Modified) ;
Coaxial coarse and fine focusing adjustable mechanism:25mm,precision:0.002mm;
Halogen lamp.

2. Microcamera :
Persyaratan :

Mikroskop berkamera dengan receiver.

Type yang sesuai :
Optilab Camera tipe Advance :

Kamera Mikroskop

• High-Quality progressive CMOS Color Image Sensor
• Video Mode : RGB24, I420
• Video Capture : Up to 1280 x 960
• Still Image Capture : Up to 2560 x 1920 atau 5 MPix (optimum 2 MPix)
• Frame Rate : Up to 30 fps
• Current Rate : < 400 mA
• DigitalClarity™ CMOS Imaging Technology (Micron Technology, Inc.)
• Superior low light performance with natural light filter
• AWB (Automatic Whiteness Balance)
• Auto Exposure Control
• Backlight Compensation
• Desktop / Laptop compatible with USB 2.0 conection

Receiver Software Optilab Viewer dan Optilab Image Raster (included)

  • Video Streaming :  real time digital video viewing with frame rate up to 30 frame per second (fps) Video Mode RGB24(8bit)
  • Image Capture (still capture) : resolution up to 2560 x 1920 (5 MPix), optimum 2 MPix.
  • Video Record : unlimited video recording (depend on hardisk capacity) on resolution to 1280 x 960 (AVI format file).
  • Object Dimension : object lateral demension measurement.
  • Scale Stamp : Showing capture scale.
  • Image Signer : Make and write image signs.
  • Manual Count : Counting selected objects.

OS  Software compatibility : Windows XP, Vista, Seven

ask for detail