Wisconsin Plankton Net and Bucket
WISCONSIN PLANKTON NET AND BUCKET ( Cat No. 40-A55)
Complete; assembled, w/SS Wisconsin Dolphin Bucket& Dolphin Adaptor. For vertical sampling only.
40-A40 Wisc Plank Sampler Sm, 63 µm w/CC
40-A45 Wisc Plank Sampler Sm, 63 µm w/o CC
40-A50 Wisc Plank Sampler STD, 80 µm w/CC
40-A55 Wisc Plank Sampler STD, 80 µm w/o CC
40-A60 Wisc Plank Sampler Med, 153 µm w/CC
40-A65 Wisc Plank Sampler Med, 153 µm w/o CC
40-A70 Wisc Plank Sampler MLg, 363 µm w/CC
40-A75 Wisc Plank Sampler MLg, 363 µm w/o CC
Replacement Net :
40-C10 Wisc Plank Sampler Repl, 80 µm
40-C20 Wisc Plank Sampler Repl, 153 µm
40-C30 Wisc Plank Sampler Repl, 363 µm
40-C40 Wisc Plank Sampler Repl, 63 µm
Atago Polarimeter,POLAX-2L
Atago POLAX-2L, Polarimeter (Cat.No.5223)
Angle rotation measuring range : +180° to – 179.95°
International sugar scale : +130° to – 130° Z
Minimum unit displayed : 0.05°C (0.1°Z)
Measurement Accuracy : Angel of Rotation + 0.100 C
Measurement Temp range : 5 to 400 C
Light Source : LED with interference filter (589 nm)
Observation tubes : 200 mm and 100 mm 1 of each
Power Source : AC100 to 240V, 50/60 Hz,/ 40VA
Dimension and weight : 43 x 22 x 30cm, 11.5kg
G-WON HITECH, Moisture meter, Model : GMK-3308
G-WON HITECH, Moisture meter, Model : GMK – 3308
Specifications :
.
Harga Rp.- , Harga tidak termasuk PPN franko Yogyakarta, berlaku September. Harga dapat berubah sewaktu-waktu.
ask for detail
Thermo Spectronic Spectrophotometer, Spectronic GENESYS 10 UV-Vis
Thermo Spectronic UV-Visible Spectrophotometer, Spectronic GENESYS 10 UV-Vis
Specifications :
Part Number 335902 Series
Spectral bandwith 5 nm
Optical Design Split-beam, garating-based, dual detectors
Wavelength:
Range 190 – 1100 nm
Accuracy ± 1.0 nm
Repeatability ± 0.5 nm
Lamp Source (typical service life) : Xenon (5 years)
Display 320 x 240 pixel backlit LCD, 3.8″ x 2.8″
Photometric:
Range : -0.1 – 3.0 A; 0.3 – 125%T; ± 9999 C
Readout : Absorbance, Transmittance, Concentration
Accuracy : 0.5% or 0.005 A, whichever is greater, up to 2 A
Noise : < 1 mA at 0 A; < 2 mA at 2 A, peak-to-peak at 340 nm
Drift : < 1 mA/hour
Stray light : < 0.1%T at 220, 340, and 400 nm
Data interface : Bi-directional RS232C (text only); parallel output in HP PCL format (text and graphics)
Cell Holder : 1-position or automatic 6-position Cell Holder
Keyboard : Membrane keypad
Software :
Absorbance/Transmittance/Concentration
Standard Curve
Absorbance Ratio
Absorbance Difference
Kinetics
Survey Scan (100 nm increments)
3-Point Net
Multiwavelength
Performance Validation
Test Storage : Up to 80 sets of test parameters
Languages Software, printouts and operator’s manual:
English, French, German, Spanish, Italian (user selectable)
Internal Printer (optional) : 40-column internal graphics
Analog Output (optional) : 0 – 1 V for -0.3 to 2.5 A
Power Requirements : Selected automatically; 100 – 240 Volts
Dimensions : 300 W x 400 D x 250 H mm (11.8″ x 15.7″ x 9.8″)
Weight : 8.6 kg (19 lb.)
Warranty : 1 year
Applications :
• Water and wastewater
• Food and beverages
• Inorganics
• Quality control of chemicals
• Life science
..
.