IndoGama.com

LABORATORY, SURVEY, EQUIPMENTS & REAGENTS (ILabS=>Indonesia Laboratory Suppliers)

INTERSCIENCE, Stomacher, Bag Light

INTERSCIENCE Bag Light

INTERSCIENCE, Stomacher, Bag Light

Berikut Spesifikasi dari interscience bag light:

Nominal volume : 400 ml

Useful volume : 50 – 300 ml

Bag size : 175 x 300 cm

Box of : 500 bags

Klik link di bawah ini untuk mendapatkan keterangan lebih lanjut produk bag light ini dan dapatkan juga penawaran ietem terbaik hanya dari kami.

ask for detail

HIRAYAMA, Digital Autoclave, Model : HVE-50

HIRAYAMA Digital Autoclave HVE-50Hirayama Digital Autoclave Model : HVE-50

Harga Rp 82.000.000 , Harga promo Netto Rp 77.900.000 franko Yogyakarta, berlaku 1 Juni 2026. Harga dapat berubah sewaktu-waktu

Klik untuk lihat harga/promo terbaru

Download brosur HVE 50

Lihat video di Youtube

Berikut deskripsi Hirayama model HVE-50

New and Economic Autoclave based on Unique Features of HV series
•    Electromechanical lock system
•    Dual-sensing interlock mechanism
•    Pulse Exhaust System
•    Memory function
•    Space-saving design
•    Process status display
•    Effective capacity : 50 liter

(more…)

HIRAYAMA, Digital Autoclave, Model : HG-50

HIRAYAMA Autoclave HG-50Hirayama Digital Autoclave Model : HG-50

Berikut ini adalah deskripsi dari Hirayama HG-50

Effective capacity :50.2liter
Chamber size(㎜) : 364φ×482H
Outer dimensions : 455×691×890
(W×D×H㎜)
Selective Steril.temp : 105℃~ 135℃
Cycle selection : 4-selection
Weight : 62㎏

Harga Call

Klik link di bawah ini untuk mendapat informasi lebih lanjut

ask for detail

.

.

HETTICH, Centrifuge, Rotofix 32 A

HETTICH Centrifuge Rotofix 32_AHETTICH, Centrifuge, Rotofix 32 A

Being the centrifuge of choice for physicians and small laboratories the Rotofix 32 carries out virtually every routine task required in practice. In the medical field it may be used for both clinical chemistry and cytology

–        Frequency : 50-60 Hz

–        Max Capacity : 4 x 100 ml

–        Max. RCF : 4,186

–       Max. RPM (speed) : 6,000 min-1

(more…)

HETTICH, Centrifuge, Hematokrit, Model : 210 + 2076

HETTICH Haematokrit-210HETTICH, Hematokrit, Model : 210 + 2076

At 16,060g sedimentation is completed in just a little over 6 minutes. At any rate, a run time of 10 minutes is sufficient. The rotor comes to a braked standstill. Each capillary is secured within its own chamber and supported by a holding tray. This holding tray serves to contain glass shards and any leakage should a tube break. It is easy to clean and disposable in the case of glass breakage. Capillaries, to be used for quantitative buffy coat analysis are centrifuge in the 20-place rotor prior to further analysis.
(more…)