IndoGama.com

LABORATORY, SURVEY, EQUIPMENTS & REAGENTS (ILabS=>Indonesia Laboratory Suppliers)

HANNA, COD Reactor, Model : HI 839800

 

HANNA COD Reactor HI839800

HANNA, COD Reactor, Model : HI 839800

COD REACTOR and Test Tube Heater 2008 Series
Harga : Rp. 17.500.000,- , Harga tidak termasuk PPN franko Yogyakarta, berlaku 1 April 2018, Harga dapat berubah sewaktu-waktu.

specifications:

Temperature of Reaction :105°C or 150°C (221°F or 302°F)
Temperature Stability :±0.5°C (±0.9°F)
Temperature Range :-10°C to 160°C (14°F to 320°F)
Accuracy :±2°C (±3.6°F)
Capacity :25 vials (dia 16 x 100 mm), one receptacle for a stainless steel reference thermometer

(more…)

HANNA, DO Meter, Model : HI 9142

HANNA DO Meter HI9142

HANNA DO Meter HI9142

HANNA, DO Meter, Model : HI 9142

DO Meter

Harga : Rp. 12.140.000,- , Harga tidak termasuk PPN franko Yogyakarta, berlaku 1 April 2018, Harga dapat berubah sewaktu-waktu.

specifications :

Range : 0.0 to 19.9 mg/L (ppm)

Resolution : 0.1 mg/L
Accuracy : ±1.5% FS
Typical EMC : ±0.8 mg/L
Deviation : with 4 m cable probe
Calibration : Manual, 1 or 2 point (zero and slope)
Temperature Compensation :  Automatic, 0 to 30°C  (32 to 86°F)

HANNA, DO Meter, Model : HI 9146

HANNA DO Meter HI9146

HI 9146 indogama

HANNA, DO Meter, Model : HI 9146

DO Meter

specifications :

Range : 0.00 to 45.00 mg/L O2
0.0 to 300 %O2
0.0 to 50.0 °C
Resolution : 0.01 mg/L O2
0.1 %O2
0.1 °C
Accuracy (@25°C/77°F) : ±1.5% Full Scale mg/L O2
±1.5% Full Scale %O2
±0.5 °C

HANNA, DO Meter, Model : HI 9147

HANNA DO Meter HI 9147

HI 9147 indogama

HANNA, DO Meter, Model : HI 9147

DO Meter

specifications :

Range : 0.0 to 50.0 mg/L (ppm) O2
0 to 600 % O2
-5.0 to 50.0°C
Resolution : 0.1 mg/L or 1% (O2) / 0.1°C
Accuracy : ±1% of reading (O2) / ±0.2°C
Typical EMC Deviation : ±2% of reading (O2) / ±1°C
Calibration : Manual, in saturated air
Temperature Compensation :  Automatic, from -5 to 50°C (23 to 122°F)
Salinity Compensation : 0 to 51 g/L (resolution 1 g/L)

HANNA, DO Meter, Model : HI 93732N

HANNA HI 93732N

HI 93732N

Hanna, DO Meter, Model : HI 93732N

DO Meter hi 93732n

specifications :
Range :   0.0 to 10.0 mg/L (ppm)
Resolution :  0.1 mg/L
Accuracy :  ±0.2 mg/L ± 3% of reading
Typical EMC : ±0.1 mg/L
Deviation
Light  : Source Light Emitting Diode @ 470 nm
Method : Adaptation of the Standard Methods for
the Examination of Water and Wastewater
(18th edition), azide modified Winkler
method. The reaction between dissolved
oxygen and the reagent causes a yellow
tint in the sample. hi 93732n